SmartBuss AVIO 14 Hub
The AVIO 14 Hub is a high-capacity, high-performance node in the SmartBuss Network that accommodates up to 14 cards including a SmartBuss SB101xx Network Card and any combination of media I/O cards. The System Hub operates as a "T" tap on the network providing connectivity for hundreds of video, audio, and data I/O devices.In a simple network multiple SmartBuss AVIO units are connected in a “Daisy Chain” topology, using standard Cat5 Network cable. The Cat5 connection methodology consists of an Upstream Main Feed and a Downstream Return Feed. One Hub is addressed as Node 0 and generates the networks Primary Reference Clock (PRC). This PRC ensures that all downstream units synchronize to the same clock domain providing deterministic throughput latency and stability necessary for I/O conversion and add/drop channel mapping across the network fabric. All upstream/downstream connections are bi-directional with add/drop functions performed along the Downstream Chain.
Each SB101xx network card includes a UDP Ethernet Control Port used by the SmartPath application to configure AVIO Hubs on the SmartBuss network. All AVIO Hubs are shipped to the system integrator with the required I/O cards pre-installed and tested.

Specifications
-
Network performance- 100Mb/s on Category 5 cable (100 meter hops)
-
1.2 Gb/s network performance on 130nm Single-mode fiber (15km)
-
14 positions for network + media I/O modules
-
I/O media modules are "hot swapped"
-
"Self-healing" ring communication redundancy
-
Dual-redundant counter rotating ring topology standard on Cat5 & optional with SB101DF fiber optics
-
Redundant power supply (optional)
-
3RU size
|
|
|
|
- AC Supply Voltage 85-268
- Input Current 2.8A @ 115V, 1.4A @ 230V
- AC Frequency 47 - 63 Hz
- DC Voltage 40A @ 5VDC
- Dimensions (HxWxD)
13.35cm x 48.26cm x 35.56cm
(5.25" x 19" x 14")
- Shipping Weight (no I/O cards) 11.09 kg (24.5 lbs)
- Operating Temperature 0o to 70o C (32o to 158o F)
- Humidity 5 - 95% RH, non-condensing
- AC Fan 30 cfm (bearing)
- MTTF > 157,000 hours
|
|
|
|

Compliance
- Satisfying CE Mark: Alarm Systems - EN50130-4
- Class A Radiated Emissions - EN55022 (CISPR22)
- Class A Conducted Emissions - EN55022
- Harmonics - EN61000-3-2
- Flicker - N61000-3-3
- Over/under voltage tolerance - EN50130-4 Sect 7
- Voltage Dip and Interruption - EN50130-4 Sect 8
- ESD - EN50130-4 Sect 9
- Radiated Susceptibility - EN50130-4 Sect 10
- Conducted Susceptibility - EN50130-4 Sect 11
- Electrical Fast Transients - EN50130-4 Sect 12
- Lightning Surge - EN50130-4 Sect 13
- UL and cUL Listed UL60950: 3rd Edition
- TUV Licensed EN60950:2000
|
|
 |